Sign In | Join Free | My entremaqueros.com
China Pasia Industries Ltd logo
Pasia Industries Ltd
PASIA INDUSTRIES LTD ————​Leading MI Cable Heating
Active Member

4 Years

Home > Electric Heat Tracing >

SS Sheath Mineral Insulated Electric Heat Trace On Fuel Oil Residue

Pasia Industries Ltd

SS Sheath Mineral Insulated Electric Heat Trace On Fuel Oil Residue

  • 1
  • 2

Brand Name : MICH

Model Number : MIEHTFOROD

Certification : ISO9001

Place of Origin : China

MOQ : 1 meter

Price : USD0.5-USD5 per meter

Supply Ability : 10 million meters per year

Delivery Time : in one month

Packaging Details : plywood crates

Conductor : copper alloy

Sheath : SS

Insulation : High Purity Magnesium Oxide

Usage : Oil tank and pipeline

Applications : Viscosity Decrease

Industry : Oil stocking

Max. Exposure Temp. (°F) Power Off : 1100

Voltages : Up to 600

Contact Now

Mineral Insulated Electric Heat Trace On Fuel Oil And Residue In Oil Depot

Mineral Insulated Electric Heat Trace on Fuel Oil and Residue in Oil Depot is a repeated certified heat trace solution to be used in oil depot for the fuel oil and residue. It is a systematical solution to provide heat accompaniment in the process pipes to prevent viscosity around the pipeline so that the pipeline and the tank can be secured in the liquid flow efficiency, phase shifts and guarantees the correct operation of the safety and fire fighting systems.

Cable Structure

SS Sheath Mineral Insulated Electric Heat Trace On Fuel Oil Residue

Application

Copper sheathed heating cable (MICU) Maximum output power(W/m)
Freezing Prevention for metal gutters and downpipes 49
Freezing Prevention for non-metal gutters and downpipes 16
Vessel and piping process temperature maintaining 59
Freezing Prevention for metal containers and pipes 59
Metal roof snow-melting 49
High-density polyethylene outer sheathed copper sheathed heating cable (MIHC)
Freezing Prevention for metal containers and pipes 26
Freezing Prevention non-metallic containers and pipes 13
Snow melting on asphalt slopes 82
Non-metallic roof ice or snow melting 26
Freezing Prevention for metal gutters and downpipes 26
Freezing Prevention for non - metallic gutters and downpipes 16
Concrete floor heating 33
Rising or defrosting prevention for cold storage ground 23
Freezing Prevention for metal containers and pipes 99

Note: when heating cables are used for heat tracing of vessels and pipes, the maximum output power must be controlled to ensure that the sheath temperature does not exceed its maximum allowable temperature or the spontaneous combustion temperature of the area (for hazardous areas).

Specification

Heating cable instruction code

MI CU-B 16K320/60/2520/220/E1

No. 1 2 3 4 5 6 7

No. Instruction
1 Sheath material CU
2 structure of cable components shown in table 1
3 cable codes shown in table 2, 3 and 4
4 length of heating cable In meter
5 Heating cable power In Watt
6 heating cable voltage In Volt
7 heating cable voltage See table 5

Cable Code

1 6 K 320

No. 1 2 3 4

Serial NO. Instruction
1 core number 1 or 2
2 Voltage grade 3=300V, 6=600V
3 conductor materials C,K
4 cold resistance ×1000 320=0.32Ω/m×1000

Table 1 Structure of Cable Element

SS Sheath Mineral Insulated Electric Heat Trace On Fuel Oil Residue

Note: Model C, F and G are suitable for being used at temperature under 65

Table 2 Heating Cable Specification (600V Single Conductor)

Cable Code Diameter HDPE Diameter Standard resistance value at +20 Maximum Production Length Unit weight
mm mm Ω/m m kg/km
16C1.7 8.2 10 0.0017 350 366.54
16C2.2 7.6 9.4 0.0022 380 307.77
16C2.9 7.0 8.8 0.0029 400 264.45
16C4 5.9 7.7 0.004 600 190.88
16C7 5.3 7.1 0.007 600 154.08
16C11 4.9 6.7 0.011 600 132.25
16C13 4.6 6.4 0.013 600 (300)☆ 125.7
16C17 4.6 6.4 0.017 600 (300)☆ 117.16
16C21 4.6 6.4 0.021 600 (300)☆ 111.9
16C25 3.7 5.5 0.025 600 (480)☆ 68.83
16C33 3.7 5.5 0.033 600 (480)☆ 63.76
16C40 3.4 5.2 0.04 600 (560)☆ 58.87
16C63 3.2 5 0.063 600 51.47
16K80 6.8 8.6 0.08 370 (140)☆ 254.18
16K100 5.2 7 0.1 450 (240)☆ 162.11
16K140 4.9 6.7 0.14 600 (270)☆ 122.55
16K197 4.45 6.25 0.197 600 (330)☆ 111.32
16K220 4.5 6.3 0.22 600 (330)☆ 102.89
16K315 4.3 6.1 0.315 600 (350)☆ 91.44
16K345 4.2 6.0 0.345 600 (370)☆ 85.9
16K450 4.0 5.8 0.45 600 (400)☆ 80.73
16K630 4.0 5.8 0.63 600 (400)☆ 77.26
16K800 3.5 5.3 0.8 600 (530)☆ 61.48
16K1250 2.8 4.6 1.25 600 40.83
16K2000 2.8 4.6 2.0 600 38.96

Table 3 Heating Cable Specification (600V Double Conductors)

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
26C3.4 12.9 0.0034 150 783.76
26C4.4 12.2 0.0044 160 701.56
26C5.8 11.3 0.0058 170 606.16
26C8.6 9.90 0.0086 180 451.43
26C11.4 9.30 0.0114 200 400.05
26C13.8 9.00 0.0138 210 375.20
26C17.2 8.60 0.0172 220 344.90
26C23 8.00 0.023 250 303.25
26C34.4 7.50 0.0344 280 269.20
26C49.2 7.10 0.0492 300 243.84
26K240 9.90 0.24 180 451.43
26K320 9.30 0.32 200 400.05
26K384 9.00 0.384 210 375.20
26K480 8.60 0.48 220 344.90
26K640 8.00 0.64 250 303.25
26K960 7.50 0.96 280 269.20

Table 4 Heating Cable Specification (300V Double Cores)

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
23C3.4 12.0 0.0034 200 708.10
23C4.4 11.3 0.0044 220 629.07
23C5.8 10.4 0.0058 240 537.73
23C8.6 9.00 0.0086 260 392.56
23C11.4 8.40 0.0114 280 343.89
23C13.8 8.00 0.0138 300 314.57
23C17.2 7.60 0.0172 320 286.27
23C23 7.10 0.023 340 252.98
23C34.4 6.60 0.0344 360 221.19
23C49.2 6.20 0.0492 380 197.64
23K160 10.4 0.16 220 508.37
23K240 9.00 0.24 240 392.56
23K320 8.40 0.32 265 343.89
23K384 8.00 0.384 280 314.57
23K480 7.70 0.48 300 291.91
23K640 7.10 0.64 320 252.98
23K960 6.50 0.96 350 216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH

Table 5 terminal specifications

Model: A, D, E Model: B
Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Voltage(V)
600 15 E2 20 E1 15 E1
600 20 E2 25 E2 20 E1
600 30 E3 40 E2 30 E2
600 50 E3 70 E2 50 E2
600 70 E3 100 E3 70 E2

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.

Corresponding reference table between the output power and sheath temperature

SS Sheath Mineral Insulated Electric Heat Trace On Fuel Oil Residue

Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.

Anticorrosive specification

Material

MICU

MIHC
Sulfate Not recommend Excellent
Hydrochloric acid Not recommend Excellent
Hydrofluoric acid Acceptable Acceptable
Phosphate Acceptable Acceptable
Carbonate Not recommend Acceptable
Organic acid Acceptable Not recommend
Alkali metal Acceptable Acceptable
Sea water Not recommend Acceptable
Chloride Data checking required Acceptable

Explosion-proof instructions

MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.

SS Sheath Mineral Insulated Electric Heat Trace On Fuel Oil Residue


Product Tags:

Mineral Insulated Electric Heat Trace

      

Viscosity Decrease Electric Heat Tracing

      

SS Sheath Heat Tracing System

      
 SS Sheath Mineral Insulated Electric Heat Trace On Fuel Oil Residue Manufactures

SS Sheath Mineral Insulated Electric Heat Trace On Fuel Oil Residue Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Pasia Industries Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2024 entremaqueros.com. All rights reserved.